SRC Standard Configuration
Previous Topic  Next Topic 


Overview


The SRC has options that can be set by sending data to the SRC.  Using the built in interface, DataXchange can easily send the needed data to adjust the SRC configuration.  The user interface can be found under the Communication tab under SRC Properties.  From there you will have access to the additional SRC configuration options.


When the Connect button is pressed the SRC will attempt to connect and detect the SRC.  Once a connection is made the configuration changes can be sent to the SRC.  When an actual connection  is made the Connect button will change to Disconnect.  When disconnected all of the Send buttons will be disabled, and when connected they will all be enabled.  While connected any data received as a response will be displayed in the large text box on the bottom of the screen.


Settings can also be set for the SRC in Offline mode.  This will allow the settings to be restored to the SRC at a later time.


Once connected to the SRC it is possible to able to modify the following settings.


       -  X Input Functions:  You are able to select and modify settings for inputs X1-X8.

       -  X Previously Sent Values:  These are the settings that are saved in the database for the selected input.

       -  Current Values:  This is the current value for the selected input.

       -  New Values to send: This setting can be adjusted to have 4 different options:  Status (default) latching low, latching high and counter.

       - Input Delay:  When Off is selected the Delay (s) text box will be hidden.  If On is selected then the Delay(s) text box will be shown.  The text box will accept positive integers less than 1000.  More on this topic can be found here.

       -  Custom Command:  Used to send a custom command.  Custom Commands are only used by Scytec support personnel.

       -  Query the SRC Setup: This will return the current setup of the SRC. Details such as firmware version, sending input state, sending input states on change, automatic sending of the input states and any delays that are set.

       -  Restore all settings to the SRC: This function can be used when replacing an SRC, or when SRC settings were configured offline.  All of the previously saved settings will be sent to the SRC. 

       -  Request Current Values:  This will return the current values for each of the SRC inputs. 

                -  Offline: SRC properties can be accessed in an offline mode. Standard and extended properties can be saved but not sent to the SRC.